• Send Us a Message
  • Skip to content

    dr-storage-f1-1200-6-ultra-low-humidity-dry-cabinet-1250l-capacity

    $10,500.00
    SKU DR-F1-1200-6

    PAIR IT WITH

    Satisfaction Guarantee

    The Dr. Storage F1-1200-6 Ultra Low Humidity Dry Cabinet is a plug and play, fully auto-dry cabinet which stables the cabinet condition at <1%RH. There is no need to set the panel buttons at all. It is specially designed for moisture sensitive SMD packages to comply with J-STD-033B.


    Just the facts for Dr. Storage F1-1200-6


      • Humidity Range: <1%RH
      • Outside Dimension: W1200" x D672" x H1815mm
      • Shelves: 5
      • Cabinet Color: black
      • Voltage: 110V/230V
      • Display Precision: ±1℃, ±2%RH
      • Software: Humidity Manager for drawing the curve of RH and temperature
      • Structure: 1mm thick carbon steel with antistatic paint
      • Door: Compression handles, airtight magnetic sealers and antistatic glass
      • Wheels: four antistatic 3” wheels, two of them with brakes
      • Grounding Wire: 1MΩ. (940mm long)
      • ESD Paint: 103~109Ω. (surface resistance)
      • Power Consumption: Ave. 135Wh; Max. 425W


    Here are some great features for the F1 Series Desiccator Cabinets:


    Data Recording - It is important to verify that the condition of storage meets the regulation of J-STD-033B. The users can connect note book PCs directly to the RS232 port of the cabinet to acquire the data or use our data logger to record the data. With our data recording function, the historical fluctuation of relative humidity and temperature can be shown clearly in the graph. The floor life of the Moisture Sensitive Devices can also be calculated in the software . This uniquely patented function can easily verify if the SMD packages are stored at proper condition. It is very convenient for those who carry out quality assurance procedures.
    Color Management - With different colors of extended bins ,users can realize visual color management for dedicated time and different projects.
    Calibration Reminding - The drift effect of sensors might influence the accuracy. In order to help complying with the regulation of ISO, a unique design of calibration expiration reminding function is offered in this model. When the sensor runs over 365 days, the decimal point in the panel will be flashed for reminding the user.
    Alert Setting - There are two ways of alert - flash and buzz. Alert can be activated when the relative humidity or temperature is higher than the setting of upper limit. The flash and buzz alert can be activated by different delay times too.


    Need more facts? Check below for our technical spec sheet just in case.
    Got a question? Send us an email info@gokimco.com or give us a call - we can help!